RA Series – SCR Pre-Regulated Linear Power Supplies
Constant Voltage / Current Limiting Power Supply.
FEATURES:
- Remote Voltage Programming
- Remote Sensing
- Series/Parallel Operation
- Rear Barrier Strip
- 1 mV RMS Ripple
- 10 Turn Voltage Control
- 10 Turn Current Control
- Optional IEEE-488, LAN, RS485, RS232 Control
- Description
- Models
- Specifications
- Available Options
- Data Sheets
Description
The RA Series SCR Pre-Regulated Linear Power Supplies are high reliability sources providing high power, stable output regulation, very low noise, and very low output ripple. This Series offers stable DC Power in 2U (3.5”) to 6U (10 .5”) High 19” Full Rack Designs, ranging from 300W to 3000W respectively.
They are ideally suited for laboratory applications and in systems where both versatility of operation and a stable output regulation are required. The RA Series operates as a constant voltage (CV) power supply for excellent voltage regulation and has built in current limiting (CL) for protection of the external load.
3 ½” Models
MODEL NUMBER | VOLTAGE | AMPS |
---|---|---|
RA20-15A | 0-20 V | 0-15 A |
RA40-10A | 0-40 V | 0-10 A |
RA60-7A | 0-60 V | 0-7 A |
RA125-3.2A | 0-125 V | 0-3.2 A |
5 ¼” Models
MODEL NUMBER | VOLTAGE | AMPS |
---|---|---|
RA20-25A | 0-20 V | 0-25 A |
RA40-20A | 0-40 V | 0-20 A |
RA60-14A | 0-60 V | 0-14 A |
RA125-6.5A | 0-125 V | 0-6.5 A |
7″ Models
MODEL NUMBER | VOLTAGE | AMPS |
---|---|---|
RA40-30A | 0-40 V | 0-30 A |
RA60-20A | 0-60 V | 0-20 A |
RA125-10A | 0-125 V | 0-10 A |
RA250-5A | 0-250 V | 0-5 A |
8 ¾” Models*
MODEL NUMBER | VOLTAGE | AMPS |
---|---|---|
RA40-50A | 0-40 V | 0-50 A |
RA60-30A | 0-60 V | 0-30 A |
RA125-20A | 0-125 V | 0-20 A |
RA250-10A | 0-250 V | 0-10 A |
10 ½” Models*
MODEL NUMBER | VOLTAGE | AMPS |
---|---|---|
RA25-100A | 0-25 V | 0-100 A |
RA40-70A | 0-40 V | 0-70 A |
*220VAC 50/60 Hz 1 Phase Standard
Input: 115 VAC or 220 VAC ±10% 50/60 Hz Single Phase depending on the model.
Output: See specific model in table.
The output is floating and either side may be grounded.
Load Regulation: 0.01% of the maximum rated voltage for a full load step.
Line Regulation: 0.01% of the maximum rated voltage for a line change within specified input voltage range.
Ripple: ≤1 mV RMS.
Response Time: The output voltage is within regulation limits in less than 100 microseconds for a ½ load step. The output voltage will remain within regulation limits for input line step within specified voltage range.
Remote Sensing: Units provided with remote sense terminals at the rear for regulation at the point of load.
Remote Programming: All units are voltage programmable at approximately 1000Ω / Volt.
Series / Parallel Operation: Two or more units may be operated in series. Two units of the same voltage and current may be operated in parallel.
Temp. Coef.: 0.02% / °C
Stability: Better than 0.05% / 8 hours at constant line, load and temperature after ½ hour warm up.
Operating Temperature: 0°C to +60°C at any combination of line, load and temperature without the need for external cooling.
Terminations: Barrier strip terminals are provided at the rear for AC input, output, sensing, remote programming, slaving and ground.
Protection: The power supply is protected by a fuse in the input line. 8¾” & 10½” models are protected by a circuit breaker. The output of the supply is protected by means of a fully adjustable current limiting circuit.
Panel Controls: Voltmeter, Ammeter, 10 turn voltage control, 10 turn current control, pilot light and ON/OFF switch. The voltage and current control is fully adjustable from 0 to Full Range by means of 10 turn panel potentiometers.
Finish: The standard front panel finish is light blue.
Size: 8¾” & 10½” Models: 19“ (WIDE) x 22” (DEEP)
All Other Models: 19” (WIDE) x 16½” (DEEP)
OPTION | DESCRIPTION |
---|---|
2 | 3-Wire Line Cord Instead of Barrier Terminal Strip for Input |
6 | Over Voltage Protection |
27 | Chassis Slides |
29 | Optional 220 VAC Input |
36 | Voltage/Voltage Programming (0-10V = Full Rated Output Voltage) |
52 | Voltage/Current Programming (0-10V = Full Rated Output Current) |
62 | 3½ Digit Digital Meters |
85 | Voltage/Voltage Programming (Isolated Input 0-10V = Full Rated Voltage) |
90 | Voltage/Current Programming (Isolated Input 0-10V = Full Rated Current) |
108 | RS232 Control with Readback |
110 | RS485 Control with Readback |
112 | IEEE-488 Control with Readback |
123 | RJ45 Control with Readback |