APPLICATIONS
FEATURES
MODELS
SPECIFICATIONS
OPTIONS

KV SERIES

High  Voltage SCR Regulated Power Supply Up to 1500V

APPLICATIONS

The KV series of power supplies are constant voltage/constant current units with automatic crossover. Models are available with up to 3 ampere current capacity over the full voltage range. Options such as remote voltage programming, remote current programming and remote power control makes the unit a versatile equipment for laboratory and manufacturing operations.

FEATURES

  • Output 0 to 1500 VDC
  • 0.5% Voltage Regulation
  • 0.5% Current Regulation
  • 0.5% RMS Ripple
  • Standard Voltmeter and Ammeter
  • Optional 3½ Digit Digital Meters
  • Optional Voltage/Voltage Programmable
  • Optional IEEE488, RS485, RS232 Control
KV Series Digital
Download PDF
Request for Quote

MODELS

5 ¼” Model

MODEL NUMBER VOLTAGE AMPS
KV1000-0.50-1000 V0-0.5 A

7” Model

MODEL NUMBER VOLTAGE AMPS
KV1000-10-1000 V0-1.0 A
KV1500-0.50-1500 V0-0.5 A

10½” Model*

MODEL NUMBER VOLTAGE AMPS
KV1000-20-1000 V0-2.0 A
KV1500-10-1500 V0-1.0 A

14” Model*

MODEL NUMBER VOLTAGE AMPS
KV1000-30-1000 V0-3.0 A
KV1500-1.50-1500 V0-1.5 A

[*10½” Model and above: 230 VAC 50/60Hz 3Ø Standard]

SPECIFICATIONS

Input: 115 VAC or 230 VAC  ±10%, 50/60 Hz single phase depending on the model.

Output: See specific model in table. Adustable 0 to rated voltage in voltage mode. Adustable 0 to rated current in current mode.

Regulation

Voltage:
Line: ≤ 0.5% for a line change within specified input range.
Load: ≤ 0.5% for a full load step.

Current:
Line: ≤ 0.5% for a line change within specified input voltage range.
Load: ≤ 0.5% for full voltage compliance over the operating range of >10% to <90% of maximum rated output.

Ripple: ≤ 0.5% volts RMS of maximum rated output.

Response Time: The output voltage is within regulation limits in less than 500 miliseconds for a  ½ load step.

Controls:

  • 10 – Turn  Voltage Control
  • 10 – Turn  Current Control
  • Voltmeter
  • Ammeter
  • Input Fuse – KV 1000-0.5, KV 1000-1 and KV 1500-1.5   Circuit breaker – all other models

Operating Temperature: 0 to 50°C without derating.

Termination:   
Input: 5 ¼” & 7″ models have 3-wire line cords. All other models have a barrier terminal strip.
Output: Barrier terminal strip at the rear.

Size:
5¼”   Model: 5¼” (H) x 19″ (W) x 16½” (D)
7″ Model: 7″    (H) x 19″ (W) x 16½” (D)
10½” Model: 10½” (H) x 19″ (W) x 16½” (D)
14″   Model: 14″  (H) x 19″ (W) x 16½” (D)

OPTIONS

OPTIONDESCRIPTION
6Over Voltage Protection
29Optional 220 VAC Input
36Voltage/Voltage Programming (0-10V = Full Rated Output Voltage)
52Voltage/Current Programming (0-10V = Full Rated Output Current)
623½ Digit Digital Meters
85Voltage/Voltage Programming (Isolated Input 0-10V = Full Rated Voltage)
90 Voltage/Current Programming (Isolated Input 0-10V = Full Rated Current)
95 Remote Output Inhibit 5 V = DC ON, 0 V = DC OFF
108RS232 Control with Readback
110RS485 Control with Readback
112IEEE-488 Control with Readback

Other options available – Consult with factory